Shop

  • Cim-Tek 400 water block element 10μ CT70060

    Cim-tek filters are an economical and effective way to remove emulsified water, particulate and micro-organism from fuel and oil. Free water is best removed using a water separator – preferably before the fuel pump, as the water does make the Cim-teks block. we recommend Separ or Racor water separators. Cim-tek elements either only take out particulate or both particulate and emulsified water. They are available with nominal cellulose filter elements as well as the much more effective absolute glass fibre based filter elements, and then with or without absorption material to eliminate the emulsified water from the fuel or oil. The latter prevents the growth of micro-organism. Different element and filter head sizes are for different pump flow rate rates. The lower the micronnage on the filter, the better it filters and removes water.

    27,45 33,21 tax incl.
  • Njord Ultra Clean Diesel Additive 250ml doseerfle48,48

    Krachtig dieseladditief met de naam Njord Ultra Clean voor een superieure brandstofkwaliteit voor motoren en opslagtanks. Het is zeer efficiënt in het reinigen van de brandstofinjectoren, pompen, brandstofleidingen en de tankwanden. Het breekt brandstofsedimenten af tot kleine stukjes die in de motor worden verbrand.

    58,33 70,58 tax incl.
  • Cim-Tek 300 microglass element 1 μ CT70025

    Cim-tek filters are an economical and effective way to remove emulsified water, particulate and micro-organism from fuel and oil. Free water is best removed using a water separator – preferably before the fuel pump, as the water does make the Cim-teks block. we recommend Separ or Racor water separators. Cim-tek elements either only take out particulate or both particulate and emulsified water. They are available with nominal cellulose filter elements as well as the much more effective absolute glass fibre based filter elements, and then with or without absorption material to eliminate the emulsified water from the fuel or oil. The latter prevents the growth of micro-organism. Different element and filter head sizes are for different pump flow rate rates. The lower the micronnage on the filter, the better it filters and removes water.

    61,90 74,90 tax incl.
  • Air Sentry L-143 in-line low air breather

    1/2″ FNPT, max water absorption capacity 145 ml ( 4.91 fl.oz.)

    max reservoir fluid flow 285 lpm or 75 gpm

    100% Silica Gel

    max air flow 10 cfm (0,285 m3/minute)

    87,49 105,86 tax incl.
  • Njord Ultra Clean Diesel Additive 5 liter – cleans 25.000 liter

    Powerful diesel additive called Njord Ultra Clean providing superior fuel quality for engines and storage tanks. It is very efficient at cleaning the fuel injectors, pumps, fuel lines as well as the tank walls. It breaks down fuel sediments to small pieces that will be burnt in the engine.

    483,46 584,99 tax incl.
  • Cim-Tek 260 particulate element 10 μ CT70094

    Cim-tek filters are an economical and effective way to remove emulsified water, particulate and micro-organism from fuel and oil. Free water is best removed using a water separator – preferably before the fuel pump, as the water does make the Cim-teks block. we recommend Separ or Racor water separators. Cim-tek elements either only take out particulate or both particulate and emulsified water. They are available with nominal cellulose filter elements as well as the much more effective absolute glass fibre based filter elements, and then with or without absorption material to eliminate the emulsified water from the fuel or oil. The latter prevents the growth of micro-organism. Different element and filter head sizes are for different pump flow rate rates. The lower the micronnage on the filter, the better it filters and removes water.

    23,01 27,84 tax incl.
  • Racor Spin-on replacement filter element R15P 30 micron

    40,44 48,93 tax incl.
  • Filter element 04030 SWK2000/40 30μ

    The SEPAR 2000 should be installed on the suction side of the fuel system, between the fuel feed tank and the engine mounted fuel lift pump.
    Install the filter in an accessible position to allow water and particulate removal and filter element change (a minimum of 60mm is required for element change)
    Separ 2000 series of fuel/water separators are compatible with B100 biodiesel.
    Separ 2000 series water separators fuel filters are a simple solution to many different fuel related problems.
    Five separate stages of filtration ensure 99.9% water separation (Certified TUV Report using SAE J1839) at maximum flow.
    Low restriction reduces wear on fuel pumps and ensures full RPMs.
    Back flushable (cleanable) element reduces down time and costly element changes.
    The ideal position for the filter is at the same height as the lift pump. However if the top of the fuel tank is above this position a full flow ball valve should be fitted, before, the filter so that the fuel flow can be shut off to allow filter maintenance.
    In applications where the fuel level is below the filter it is still advisable to install a full flow ball valve to prevent fuel draining back into the fuel tank.

    45,34 54,86 tax incl.
  • Visual Water Alarm Module 12 VDC

    54,66 66,14 tax incl.
  • Njord Micro-Organism Test Liqui-Cult

    Liqui-Cult test are used to detect microbial growth in fluids, in the laboratory and in the workplace. Areas of application included metalworking fluids, circulating cooling and process water, hydrocarbons, and other liquids such as cleaners, cosmetics, liquid soaps and detergents, etc.

    205,70 248,90 tax incl.
  • Njord Fuel Conditioner NFC-500A

    Njord Magnetic Fuel Conditioners drastically reduce particle size in in diesel fuel, lube and hydraulic oils and other light distillates. Smaller particles mean less deposits on injectors, pumps, valves and tanks plus a better combustion as large particles cause incomplete combustion and formation of soot. Smaller particles also reduce the number of filter changes, and let you go down in micronnage of your filters. Because the injecots stay cleaner, the injeciton pattern is better and the consumption lower.

    Next to that they stop microbial growth that can lead to the build-up of cellular product (jelly-like slime) produced by the organisms which block filters. Njord Fuel Conditioners provide the magnetic conditioning chamber which causes induction to occur in microbes suspended in the fuel and passing through the flow path of the Njord Fuel Conditioners. This action disrupts the electrical balance of the cell membrane, preventing it from colonizing and producing the corrosive acids and the cellular slime that coats tanks and blocks fuel filters. In this fashion they control microbial contamination.

    447,96 542,03 tax incl.
  • Njord Micro-Organism Test Liqui-Cult – Single Test Bottle

    Liqui-Cult test are used to detect microbial growth in fluids, in the laboratory and in the workplace. Areas of application included metalworking fluids, circulating cooling and process water, hydrocarbons, and other liquids such as cleaners, cosmetics, liquid soaps and detergents, etc.

    33,00 39,93 tax incl.
0
    Your Cart
    Your cart is emptyReturn to Shop